Flow beneath a sluice gate procedure
WebThe goal of this experiment is to define the relationship between upstream head and flowrate for water flowing under a sluice gate; calculate the discharge coefficient; to observe the flow pattern; and to determine the relationship between upstream head and thrust on a sluice gate. Background. The flow of liquids in open channels can be ... WebThe flows through a sluice gate or a tainter gate are approximated in FEQUTL by computing a series of 2-D tables: one table for each of a series of gate openings. When the gate opening is fixed, the flow is defined for given upstream and downstream water …
Flow beneath a sluice gate procedure
Did you know?
WebDefining a reference velocity: • v2 = Cd (2gy1)1/2. The unit-width discharge under a rectangular sluice gate is: • q = v2 y2. The contraction coefficient Cc varies within a narrow range, between 0.598 and 0.611. A value of Cc = 0.61 has been recommended for … WebJan 1, 1992 · Sluice‐gate discharge coefficient is an involved function of geometric and hydraulic parameters. For free flow, it is related to upstream depth and gate opening, whereas for submerged flow, in addition to these parameters, it depends on tail‐water depth. The present practice of discharge coefficient determination is from curves drawn ...
WebMDPI - Publisher of Open Access Journals WebC C C FH (N) F/FH g SI. y, Y2 V N (m) (m) (m3) Q. Qa (m3/s) (m3/ s) (N) 1 9.6 1.5 19349.2 1544 1290 0.89 1 0.83 0.023 0.03 0.72 2 2 3 Data measured: Cross sectional area of the measuring tank=61 cm X 30.5 cm= 1860.5 cm Initial gauge Reading ,x, = 9 cm Final gauge Reading , x2 = 19.4 cm Width of sluice gate , b = 7.6 cm Time, t= 15 sec Elevation of …
http://connectioncenter.3m.com/sluice+gate+lab+report WebAdditional Stainless Steel Flow Control Options. Slide gates are just one of many items available for controlling water or wastewater flows. Two additional popular options are flap gates and stop logs. Flap gates are available in multiple shapes and sizes for use with both channels and pipes, offering a simple way to prevent return flow under ...
Webproperties of flow beneath a sluice gate using a physical model to analyse the profile of water surface around the sluice gate. Sepulveda et al. [13] studied different calibration methods for the discharge coefficient of submerged sluice gates. They found that the value 0.611, gives good results within the practical ...
Websluice gate is drawn tightly to the wall thimbles. 4. The mounting flange of the sluice gate should be thoroughly cleaned. Care should be taken to prevent damage to machined surfaces. 5. The gate can then be lifted and set over the studs, and nuts put in place and tightened. The sequence of tightening should be as indicated in the drawings below. greene king essex veterans football leagueWebJan 1, 1992 · Emphasis is given to the flow conditions after the sluice gate, hydraulic jump formation and the effectiveness of the flow control, which is the main function of such structures. flugelhorns at dillon musicWebJan 1, 1999 · Similar to an ordinary sluice gate, the discharge below gates located over sills in rectangular channels may be expressed as: (1) q = C d G 2 g (H − Z) where q is the discharge per unit width, H is the upstream flow depth above the channel bed, G is the gate opening, Z is the sill height above the bed, g is the gravitational acceleration and ... flugelhorn mouthpiece tapersWebthe sluice gate on the location and type of hydraulic jump (Table 2). The experimental results demonstrate that the hydraulic jump approaches the sluice gate as the gate opening increases till the gate becomes submerged. The reason behind this fact may owe to the decline in the velocity under gate as it is raised and accordingly the speciic flugelhorn players famousWebhydrostatic. Some of them are invalid for the flow immediately downstream from the gate section. According to Frisch et al. (2004), when the ratio of the upstream flow depth, y1, to the sluice gate opening, w, is large, the flow velocity at the vena contracta, v2, can be … flugelhorn mouthpiece reviewsWebFlow under a sluice gate and the calibration of sluice gates are classical problems in hydraulics, but despite many decades of research, universal calibration accuracy has remained elusive. The primary causes are the complexity and variability of the flow situation. Both free and submerged flow are possible, gate seals have an important ... flugelhorn solo repertoireWebThe main aim of this study is to conduct a series of laboratory experiments to determine Cd for inclined slide gates. These tests and models were used to evaluate both free and submerged flows ... flugelhorn tapered leadpipe